Skip to main content

Jacket material

  • PVC YM4 according to VDE 0207, part 52, hardly inflammable, permanent operating temperature T = -45 ° C up to + 105 ° C
  • TPU 11YM1, according to VDE 0282, part 10, good abrasion and tear resistance, hardly inflammable, permanent operating temperature, T = -60 ° C up to + 120 ° C

Heat Insulation

  • Thermo fleece (temperature resistant up to 200 °C)
  • Glass fibre fleece (temperature resistant up to 500 ° C)

Use

  • Lengths up to 300 m, fixed installation, indoor and outdoor installation
  • Frost protection, holding temperature up to approx. 30 ° C, holding temperatures up to approx. 140 ° C (depending on the heating tape in EX version)
  • ATEX Zone 1+2 / 21+22 / T2 / T3 / T4 / T6

PSG Ex2 Extruded SR Brochure 

Datasheet PSG Ex2 Heated Sample Line 

Installation and start up guide for PSG-Ex2 Sample lines