Features

  • Largest active filter surface on market
  • Corrosion resistant, made of stainless steel SS316Ti
  • Very compact design
  • Controlled heating to 180°C
  • No cold spots
  • Filter change without any tools
  • Test gas connection as standard
  • Protective housing for external mounting
  • Temperature alarm contact

Technical Data
Process gas sampling conditionsDust contentmax. 3 g/m3
Temperaturemax. 1800°C
Pressure50 – 600 kPa
HeatingTemperature180°C (315°C)
Temperature alarm150°C (285 °C)
ControllingThermostatically or self-regulating
FilterMaterialCeramic surface coated
Porosity0,3 µm
CharacteristicsParts in contact with medium1.4571, FPM
Dead volume280 ml
Tightness104 hPa l/s