Skip to main content

BCR Sample Gas Coolers

BCRs are the allround talents among refrigerated coolers. They are installed in all applications where pure coolers are needed without additional conditioning equipment. BCR sample gas coolers can be optionally equipped with PVDF-, glass- and/or stainless-steel-heat-exchangers. Thus BCR sample gas coolers can cool down nearly every gaseous medium. The coolers are also very suitable for high gas flow rates and extreme high inlet temperatures. Even for operation in explosive atmosphere ATEX zones 1 and 2 BCR offers high performance systems.

  • 1-8 gas paths (PVDF, glass, stainless steel ), 90-500Nl/hr per gas path, max. inlet temp. 140°-180°C
  • high-performant exchangeable heat-exchanger in div. material-variants, universal applicable
  • wall-mount housing in front- and side-design, console-mounting, mobile versions
  • EEx-version for operation in ATEX zones 1 and 2

BCR 01 Sample Gas Cooler

Features

  • 1 Gas path (PVDF, glass, stainless steel)
  • 125-250Nl/hr per gas path
  • Digital temperature display, alarm contact function
  • Wall-mount housing (front/side), mobile versions
  • Condensate pump optional

Technical data
Number of gas paths 1
Heat-exchanger type 1 x Mono
Heat-exchanger material PVDFGlassSS316
Sample gas flow rateNl/hr1 x 1251 x 1501 x 250
Dead spaceml1 x 671 x 981 x 67
Gas inlet temperature max.°C140160180
Gas dew point at outlet°C3  +/-0,5
Ambient temperature°C+5 to +45
Dimensionsmm185 x 300 x 355
Weightkg16,5
  • BCR01-Brochure



BCR 02 Sample Gas Cooler

Features

  • 1-2 Gas paths (PVDF, glass, stainless steel)
  • 90-350Nl/hr per gas path
  • Digital temperature display, alarm contact function
  • Wall-mount housing (front/side), mobile versions
  • Condensate pumps optional

Technical data
Number of gas paths 12
Heat-exchanger type 1 x Mono1 x Dual
Heat-exchanger material PVDFGlassSS316PVDFSS316
Sample gas flow rateNl/hr1 x 1801 x 2001 x 3502 x 902 x 150
Dead spaceml1 x 671 x 981 x 672 x 552 x 55
Gas inlet temperature max.°C140160180140180
Gas dew point at outlet°C3  +/-0,5
Ambient temperature°C+5 to +45
Dimensionsmm230 x 300 x 355
Weightkg18,519,0
  • BCR02-Brochure



BCR 03 Sample Gas Cooler

Features

  • 1-4 Gas paths (PVDF, glass, stainless steel)
  • 125-500Nl/hr per gas path
  • Digital temperature display, alarm contact function
  • Wall-mount housing (front/side)
  • Condensate pumps optional

Technical data
Number of gas paths 124
Heat-exchanger type 1 x Mono2 x Mono2 x Dual
Heat-exchanger material PVDFGlassSS316PVDFGlassSS316PVDFSS316
Sample gas flow rateNl/hr1 x 2501 x 3001 x 5002 x 2502 x 3002 x 4004 x 1254 x 150
Dead spaceml1 x 671 x 981 x 672 x 672 x 982 x 674 x 554 x 55
Gas inlet temperature max.°C140160180140160180140180
Gas dew point at outlet°C3  +/-0,5
Ambient temperature°C+5 to +45
Dimensionsmm450 x 300 x 300
Weightkg21,023,0
  • BCR03-Brochure



BCR 04 Sample Gas Cooler

Features

  • 1-8 Gas paths (PVDF, glass, stainless steel)
  • 125-500Nl/hr per gas path
  • Digital temperature display, alarm contact function
  • Console-mount housing
  • Condensate pumps optional

Technical data
Number of gas paths 48
Heat-exchanger type 4 x Mono4 x Dual
Heat-exchanger material PVDFGlassSS316PVDFSS316
Sample gas flow rateNl/hr4 x 2504 x 3004 x 5008 x 1258 x 150
Dead spaceml4 x 674 x 984 x 678 x 558 x 55
Gas inlet temperature max.°C140160180140180
Gas dew point at outlet°C3 +/-0,5
Ambient temperature°C+5 to +45
Dimensionsmm230 x 300 x 3500
Weightkg39,042,0
  • BCR04-Brochure



BCR 05 EEx Sample Gas Cooler

Features

  • 1-4 Gas paths (PVDF, glass, stainless steel)
  • 125-400Nl/hr per gas path
  • Analogue temperature display, alarm contact function
  • Console-mount housing
  • EX II 2G Ex px de [ai] IIC T4 Gb, for ATEX zones 1 and 2

Technical data
Number of gas paths 124
Heat-exchanger type 1 x Mono2 x Mono2 x Dual
Heat-exchanger material PVDFGlassSS316PVDFGlassSS316PVDFSS316
Sample gas flow rateNl/hr1 x 2501 x 3001 x 4002 x 2502 x3002 x 3504 x 1254 x 150
Dead spaceml1 x 671 x 981 x 672 x 672 x 982 x 674 x 554 x 55
Gas inlet temperature max.°C130
Gas dew point at outlet°C3  +/-0,5
Ambient temperature°C+5 to +45
Dimensionsmm440 x 350 x 470
Weightkg38,540,5
  • BCR05-Brochure



BCR 06 Sample Gas Cooler

Features

  • 1 Gas path (PVDF, glass, stainless steel)
  • 180-350Nl/hr per gas path
  • Digital temperature display, alarm contact function
  • Portable or wal mounting
  • Condensate pump, filter, flow meter, liquid sensor and sample gas pump as option
Technical data
Number of gas paths1
Heat-exchanger type1 x Mono
Heat-exchanger materialPVDFGlassSS316
Sample gas flow rateNl/hr180200350
Dead spaceml679867
Gas inlet temperature max.°C140160180
Gas dew point at outlet°C3 +/-0,5
Ambient temperature°C+5 to +45
Dimensionsmm230 x 300 x 430
Weightkg18,5
  • BCR06-Brochure